Data center environmental impact and site planning, before anyone breaks ground.
A free tool for county planners, commissioners, residents and developers. Place a proposed data center on real laser-scanned terrain and see its runoff, water use, noise, power and emissions before, during and after construction, while the site plan can still change.
Bring your own site
The Cumming scan is only an example. Upload a drone survey, county LiDAR or a USGS elevation file from anywhere, and Aglorify rebuilds the 3D site and reruns every check on it. Soils and land cover load automatically anywhere in the U.S.; county zoning is loaded for Forsyth County, Georgia so far.
Set up your data center
Before and after development, side by side
What changes on the disturbed area at each stage. Use Split-screen compare above the 3D view to see two stages at once, and the Runoff change map to see where flows rise downhill.
Planning review: zoning and permits
Watershed and terrain analysis: where the water goes
Water impacts don't stop at the property line. Follow the site's runoff downstream, or pick any point to see everything that drains to it.
Stormwater runoff analysis by design storm
Heavier-rain scenarios are sensitivity tests, not forecasts. Future rainfall projections vary widely between studies, so we show how much the answer changes rather than pick one projection. The U.S. National Climate Assessment reports that heavy downpours are increasing in the Southeast; NOAA Atlas 15 will replace Atlas 14 when it covers Georgia. The USGS check below always uses published rainfall.
Green infrastructure: keeping rain where it falls
Runoff-reduction credits: Georgia Coastal Stormwater Supplement (2009), Table 7.1. Design references suggested by a UGA hydrology professor: the San Mateo Countywide Green Infrastructure Design Guide (3rd ed., 2024) and the Delta Institute Green Infrastructure Design Guide. A screening estimate: real practices are sized by an engineer from soil tests and the site plan.
Runoff check against USGS estimates
USGS estimates: Scientific Investigations Report 2023-5006 regression equations for rural Georgia streams, run through USGS StreamStats in October 2026 at the two points above. Our numbers are computed live from the scanned terrain and NLCD land cover, with no tuning to match.
Water usage and supply
Consumptive use and wastewater assume a cooling tower at 4 cycles of concentration (75% evaporated, 25% blowdown). Water estimates at the proposal stage change often, so treat these as a starting point for questions.
Noise at the property line
Air quality and generator emissions
Why no heat map: the exhaust heat from cooling equipment doesn't show up in satellite data, so measuring it would take a climate model or monitors on site. For rural sites, experts we consulted expect air pollution and water use to matter more than local warming.
Electric power: what the utility will need to know
These questions come from feedback by an executive at a Georgia electric cooperative. Aglorify does not model the grid itself; utility capacity, prices and transmission limits are not public at the site level, so the answers have to come from the serving utility and the applicant.
Ecosystems, light and community commitments
Precautionary principle. When a project could cause serious or irreversible harm, decision-makers can act before the harm is fully proven and ask the applicant to show the project is safe. In practice: require the applicant's own studies (acoustic, lighting, water, air dispersion) before approval, not after. These questions come from feedback by Georgia Tech sustainability and planning faculty.
Environmental rule check
How this placement compares with environmental rules that apply in Forsyth County and Georgia. For an imported site elsewhere, these are Forsyth's numbers used as an example. A screening check that shows what to verify, not a permit review.
Why the data center sits here
Scan your own site, anywhere
There are two kinds of scans, and they answer different questions. A phone's LiDAR reaches about 5 meters, which is enough for a building, a cooling yard or a server room but not a 40-acre site, so a phone can't scan a whole region. Site-scale terrain comes from a drone survey or aircraft LiDAR, like the USGS scan above. Free USGS elevation files cover almost all of the U.S. at the National Map.
Site terrain: drone or LiDAR
Drop an elevation file and Aglorify rebuilds the 3D site, then reruns drainage, runoff, siting and the rule check on it. Files can come from a drone survey (DroneDeploy, OpenDroneMap), county LiDAR, or the USGS National Map. Clip to your parcel first.
Optional: where the site is, if the file doesn't say. Aglorify uses it to load soils, land cover and (in Forsyth County) zoning.
Optional: local 24-hour rainfall in inches from NOAA's precipitation frequency server. Without it, Cumming's rainfall is used.
Buildings and equipment: phone scan
Scan an existing facility with Polycam, Scaniverse or 3D Scanner App on an iPhone or iPad (LiDAR on Pro models; photo mode on any phone). Export a .glb, .ply or .obj and drop it here to measure it, then use its footprint for the site above.
Method and sources
Everything runs in your browser, so you can check the numbers by changing the inputs. Estimates are screening-level: they show where to look and what to ask, not engineering results.
| What | How it's computed | Source |
|---|---|---|
| Terrain | Elevation averaged to a 150 × 150 grid (about 16 × 19 m cells for the Cumming scan). Imported files are resampled to the same grid. | USGS 3D Elevation Program |
| Drainage | Fill sinks, send each cell to its steepest downhill neighbor (D8), count upstream area; channels drain 25 ha or more. Computed, not a surveyed stream map. | Standard GIS hydrology method |
| Rainfall | Partial-duration intensity–duration–frequency table for 34.255° N, 84.180° W; durations between table values are interpolated on log–log axes | NOAA Atlas 14, Vol. 9, v2 |
| Land cover | NLCD 2021 (30 m) resampled to the scan grid; for imported sites it is loaded from the MRLC map service. Each class gets a runoff coefficient and an NRCS curve number for its soil group. | MRLC, NLCD 2021 Land Cover |
| Soils | Hydrologic soil group (A to D) for every grid cell from the soil map unit at its center; dual groups such as B/D use the undrained group. Curve numbers come from NRCS TR-55 Table 2-2 for each land cover and soil group. Loaded live for any U.S. site; falls back to group B if the service is down. | USDA NRCS SSURGO, Soil Data Access |
| Zoning and overlays | Zoning districts, tax parcels, comprehensive plan character areas, stream buffers and setbacks, wetlands, HUC-12 watersheds, zoning cases and river corridors, loaded live and drawn onto the grid. Checked against UDC Table 14.1 and Section 16-4.10, and compared with Cobb County's Chapter 134. | Forsyth County GIS open data; Forsyth UDC; Cobb County Chapter 134 |
| Watershed | Upstream area: every cell whose D8 flow path reaches the chosen point. Downstream: the steepest-descent path to the edge of the scan. | Standard GIS hydrology method |
| Runoff (Rational) | Q = C·i·A, with i taken at each surface's time of concentration (Kirpich: ×1.5 today's cover, ×1 bare soil, ×0.4 paved; minimum 10 min). C from land cover today; 0.50 bare soil, 0.95 roof and pavement, 0.20 lawn. | NCDEQ Stormwater Design Manual, Table 1 |
| Runoff (NRCS) | TR-55 graphical peak discharge, Type II rainfall: runoff depth Q = (P − 0.2S)²/(P + 0.8S), S = 1000/CN − 10; peak = qu·A·Q. Bare soil, lawn and woods curve numbers follow the soil group (for group B: 86, 61 and 55); roofs and pavement 98. Each table cell shows the range between the two methods. | USDA NRCS TR-55 (1986) |
| Detention | Modified Rational Method: storage = largest gap, over storm durations, between built-site inflow and an outflow capped at today's peak | Standard screening method |
| Validation | Peak flows at two points on the receiving creek compared with USGS regression estimates and their 90% prediction intervals | USGS StreamStats; SIR 2023-5006 |
| Stream buffers | Distance from the disturbed area and the footprint to the nearest computed channel or mapped stream, compared with 25 ft (state), 50 ft undisturbed and 75 ft impervious (county) | Forsyth County buffer checklist |
| Water | IT energy × WUE (0.55 L/kWh evaporative; 0.06 closed-loop) at 75% load; peak day = 4.5× average | Han et al. 2026, "Small Bottle, Big Pipe" |
| Power | IT MW × PUE 1.11 (hyperscale average) | Han et al. 2026, operator data |
| Noise | From the cooling yard (10 m up) to every cell: L = Lw − 20·log10(r) − 8 − 0.005·r − max(ground effect, terrain barrier). Ground effect uses the ISO 9613-2 simplified method; terrain barriers use the path difference over the highest ridge (Maekawa, 500 Hz, capped at 20 dB). Two cases: an assumed Lw of 118 dBA per 200 MW, and equipment running at the chosen night limit at a property line 100 ft from the building. | ISO 9613-2:2024; assumed sound power, to be replaced by manufacturer data; Appen Media |
| Backup generators | Generators sized to the facility load plus 20%, in 3 MW units. NOx at 6.4 g/kWh (EPA Tier 2 limit for engines over 560 kW) or 0.024 lb/hp-hr (uncontrolled); PM at 0.2 g/kWh; 50 hours a year for testing, 200 hours as a permit cap. | EPA AP-42, Section 3.4; Georgia EPD permit, Data Center Fulton |
| Grid emissions | Facility energy at 75% load × 717.4 lb CO2e/MWh (Georgia, total output); a typical car emits about 4.6 metric tons of CO2 a year | EPA eGRID2023; EPA |
| Buildings, roads, streams | Building outlines, roads and mapped waterways; buildings are counted inside each noise ring. Not available for imported sites. | OpenStreetMap contributors (ODbL) |
| Earthwork | Volume to level the footprint to its average elevation | This prototype |
Not yet included: county zoning outside Forsyth County, rainfall that loads automatically for any location, a full hydrograph model for sites over about 100 acres, storm pipes and culverts, private wells and traffic. Waste heat would need a climate model or on-site monitors rather than satellite data. Those are next. OpenStreetMap buildings are community-mapped and may be incomplete.